Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem ; 326: 127009, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32438230

RESUMO

A rapid Surface Enhanced Raman Spectroscopy (SERS) method to detect SO2 in wine is presented, exploiting the preferential binding of silver nanoparticles (AgNPs) with sulfur-containing species. This interaction promotes the agglomeration of the AgNPs and inducing the formation of SERS "hot spots" responsible for SO2 signals enhancement. For increasing SO2 concentrations from 0 to100 mg/l in wine simulant, SERS intensity showed an increasing trend, following a Langmuir absorption function (R2 = 0.94). Due to the wine matrix variability, a standard additions method was then employed for quantitative analysis in red and white wines. This method does not require the SO2 separation but only a matrix pre-cleaning by solid phase extraction. The limit of detection (LOD) was defined for each wine tested, ranging from 0.6 mg/l to 9.6 mg/l. The results obtained were validated by comparison with the International Organization of Vine and Wine method (OIV-MA-AS323-04A).


Assuntos
Dióxido de Enxofre/análise , Vinho/análise , Coloides/química , Limite de Detecção , Nanopartículas Metálicas/química , Prata/química , Extração em Fase Sólida , Análise Espectral Raman
2.
Molecules ; 24(10)2019 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-31109011

RESUMO

A simple procedure for field fish sample pretreatment was developed. This treatment in combination with square wave anodic stripping voltammetry (SW-ASV) with solid gold electrodes (SGE) and gold nanoparticle-modified glassy carbon electrodes (AuNPs-GCE) was applied for the determination of total mercury content. A certified reference material (CRM, Tuna Fish BCR 463), ten freeze-dried samples of canned tuna and two fresh fish samples were analysed both with a bench-top voltammetric analyser after microwave digestion and with a portable potentiostat after mild eating using a small commercial food warmer. The results obtained by the two SW-ASV approaches and by a Direct Mercury Analyser (DMA), the official method for mercury determination, were in very good agreement. In particular, (i) the results obtained with in field procedure are consistent with those obtained with the conventional microwave digestion; (ii) the presence of gold nanoparticles on the active electrode surface permits an improvement of the analytical performance in comparison to the SGE: the Limit of Quantification (LOQ) for mercury in fish-matrix was 0.1 µg L-1 (Hg cell concentration), corresponding to 0.06 mg kg-1 wet fish, which is a performance comparable to that of DMA. The pretreatment proposed in this study is very easy and applicable to fresh fish; in combination with a portable potentiostat, it proved to be an interesting procedure for on-site mercury determination.


Assuntos
Ouro/química , Mercúrio/análise , Atum , Animais , Eletrodos , Conservação de Alimentos , Limite de Detecção , Nanopartículas Metálicas/química
3.
RSC Adv ; 9(34): 19844-19854, 2019 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-35519402

RESUMO

Ochratoxin A (OTA) is one of the most important dietary risk factors and is classified as a possible carcinogen to humans. Assessing the conditions to remove it from foodstuffs in a simple and effective way is of the utmost importance. OTA behaviour in water in the pH range 1.0-12.5 was elucidated to investigate the conditions for irreversible toxicity inactivation of OTA. The results indicate that four forms, from neutral to trianionic, intervene depending on the pH. pK a1,2 were rigorously established by independent spectroscopic techniques to overcome the scarcity of literature. Then, Density Functional Theory (DFT) calculations were used to determine the most probable degradation mechanism and this was confirmed by fluorescence spectroscopy. At pH 12.5, hydrolyzation of the lactone ring starts in less than one hour, but only after two hours does the degradation process lead to fragmentation. After one week this process is not yet completed. The reaction products occurring upon re-acidification were also investigated. OTA degradation is still reversible if acidic conditions are promptly restored, yielding again a hazardous molecule. However, degradation becomes irreversible after fragmentation. This finding suggests proceeding with due caution if a base is exploited to remove the toxin.

4.
Rev Sci Instrum ; 78(11): 113902, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18052483

RESUMO

A plane capacitor cell with variable gap has been designed in order to detect the complex permittivity of low conductive liquids (up to 500 microS/cm) and the impedance of the sample-electrode interface. The novelty of the cell consists of the simultaneous presence of the field uniformity ensured by a guard ring, an adjustable gap between 300 microm and 6.75 mm (the electrode axial motion avoiding any rotation), and the immersion of the capacitor in the sample reservoir. The size of the capacitor electrodes and the gap values have been tested via the capacitance detection of the in-air cell at 1 kHz. The sample measurements have been performed by scanning the frequency range between 15 Hz and 2 MHz at four different capacitor gap values. In the paper a method to directly extract the bulk complex permittivity and the interface impedance versus frequency is presented. It is based on the assumption that the interface contribution is independent of the electrode gap, as confirmed (within the measurement accuracy) from measurements on all samples investigated. As samples of interest, we have chosen two certified electrolytic conductivity standards, KCl aqueous solutions having conductivity traceable to SI units; and two polymer latex aqueous dispersions of microspheres. Regarding KCl solutions, the conductivity measurements are compatible with the reference values within the specified uncertainty; the measured permittivities are consistent with the literature. For all samples, we have recovered the expected result that the interface impedance mainly affects the low frequency range (f<10 kHz).


Assuntos
Impedância Elétrica , Eletroquímica/instrumentação , Microeletrodos , Microfluídica/instrumentação , Soluções/química , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Microfluídica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...